Common Area Rewires for Owners Corporations in Melbourne
Rewiring common areas — stairwells, corridors, car parks and plant rooms — bringing the building up to current Australian standards.
Common Area Rewiring
Common areas in older buildings often have wiring that no longer meets current standards. A common area rewire addresses:
- Stairwell and corridor wiring – outdated cables, missing earthing and inadequate circuit capacity
- Car park wiring – exposed cables, damaged conduits and insufficient power for lighting and outlets
- Plant room wiring – wiring to lifts, pumps, HVAC and other building services that may be decades old
- Roof and external wiring – exposed wiring that has degraded from weather and UV exposure
When It Is Needed
Common area rewires are typically needed when:
- Defect notices – ESV or the distributor has issued a defect notice for the common area wiring
- Building survey – a building inspection has identified wiring that no longer meets AS/NZS 3000
- Frequent faults – common area lights, power points or equipment are tripping or failing regularly
- Planned upgrades – adding new lighting, security systems or EV charging that the existing wiring cannot support
Legacy Building Upgrades
Older buildings present unique challenges:
- Lead-sheathed cables – older buildings may have lead-sheathed or cloth-insulated cables that must be replaced
- Conduit access – existing conduits may be blocked or too small for modern cables, requiring new trunking
- Asbestos – older buildings may have asbestos-containing materials near wiring routes, requiring licensed removal before electrical work
- Structural constraints – concrete and masonry walls require core drilling and surface-mounted trunking
We have experience working in heritage and legacy buildings — we plan around the constraints and deliver a compliant installation.
What to Expect
Frequently Asked Questions
Will residents lose power during the rewire?
We plan the work to minimise disruption. Common areas may lose power in stages — for example, one floor at a time. We provide advance notice and complete each section as quickly as possible.
How long does a common area rewire take?
A small building (20–30 units) typically takes 3–5 days. Larger buildings may take 1–2 weeks. We provide a detailed timeline in the quote.
Can the rewire be done while residents are living in the building?
Yes — we work around the residents. Noisy work (core drilling, chipping) is scheduled during business hours. We keep common areas safe and accessible throughout the project.
Premium Service,
Quality Results,
Since 1963.
Over 63 years of trusted service across Melbourne
★★★★★