Heavy-Duty Outlets for Commercial Sites in Melbourne

High-current commercial outlets — 15A, 20A and 32A connections for equipment, machinery and high-power appliances.

High-Current Commercial Outlets

Commercial environments demand more power than standard 10A outlets can provide:

  • 15A outlets – colour-coded grey, used for medium-power equipment and some air conditioners
  • 20A outlets – colour-coded red, used for commercial kitchen equipment, heat pumps and ducted heating
  • 32A outlets – colour-coded orange, used for high-power machinery, EV chargers and workshop equipment

Heavy-duty outlets use larger pins and different keyways to prevent plugging a standard plug into a high-current socket — this prevents overloading and fire risk.

Equipment Power

Commercial equipment that requires heavy-duty outlets:

  • Kitchen equipment – commercial ovens, dishwashers, refrigeration and cooktops
  • Air conditioning – split systems, ducted systems and multi-split units
  • Workshop machinery – welders, saws, compressors and lathes
  • EV chargers – commercial and public EV charging stations
  • Server rooms – high-density IT equipment and UPS systems

Circuit Protection

Every heavy-duty outlet requires dedicated circuit protection:

  • Dedicated circuit breaker – sized to the outlet rating and cable size
  • RCD protection – mandatory for all commercial outlets
  • Correct cable gauge – cable size is calculated based on current rating and run length
  • Circuit labelling – every outlet and circuit breaker is labelled for identification

What to Expect

1

Load Assessment

We calculate the power requirements of your equipment and determine the correct outlet rating and cable size.

2

Quote

Fixed-price quote including the outlet, dedicated wiring, circuit breaker and any switchboard space needed.

3

Installation

We run the correct cable gauge from the switchboard to the outlet, install a dedicated circuit breaker and mount the outlet. Everything is tested and labelled.

Frequently Asked Questions

Can I use an extension lead with a heavy-duty outlet?
No — heavy-duty outlets must connect directly to the equipment via a matching heavy-duty cable. Extension leads are not rated for high-current use and create a fire risk.
Do heavy-duty outlets need a dedicated circuit?
Yes — every heavy-duty outlet must be on its own circuit from the switchboard. It cannot share a circuit with standard outlets or lighting.
How thick does the cable need to be?
Cable size depends on the current rating and run length. A typical 15A circuit uses 2.5mm² cable, a 20A circuit uses 4mm², and a 32A circuit uses 6mm² or 10mm² for longer runs.

Premium Service,
Quality Results,
Since 1963.

Over 63 years of trusted service across Melbourne

Ready when you are

Click to add photos or drag & drop

JPEG, PNG, WebP, GIF, HEIC up to 20MB each

Prefer to call?

03 9853 2644

7:30am – 4pm
Business Days

Gold Master Electrician
Energy Safe Victoria
Working With Children Check
Get in touch Call us